    10kwh home/industry storage system

    1. System Summary

    10kwh home/industry storage system use grid system, include about inverter, lithium ion battery pack, battery BMS system, power switch, and information display parts, etc. Home/industry storage system can provide stabilized rate and constant voltage AC electric, such as servers, display power, medical equipment, home electric equipment, industry equipment, etc. When the AC grid normally running, storage system could let the home loading to connect with AC grid, and also can support the solar PV to charging the battery which inside of the system; When the AC grid have some accidents, the system will start the contravariant function, it will transfer the DC current from li ion battery to AC and connect the home loading.

     

    2. Application frame

    ??17.png

    3. The specification of 10kwh home/industry storage system

    Model (KWH)

    10

    Inverter model  (KW)

    5

    Solar Controller (W)

    5000

    Charger (A)

    40

    Voltage of Battery pack(VDC)

    51.2

    Capacity of battery (Ah)

    100

    Weight  (KG)

    125

    System AC input (VAC)

    110/220  grid

    Inverter AC output (VAC)

    110/220

    The voltage wave of inverter output

    Pure sine wave

    The output rate of inverter

    50Hz±0.3Hz/ 60Hz±0.3Hz  (Options)

    Noise  (dB?1m)

    ?60dB

    Running environment Temperature/humidity

    -10~45?/0-90%

    Storage environment Temperature/humidity

    -20~55?/0-90%

    Water proof

    IP20

     

    4. The specification of solar inverter

    Solar inverter Specification

    Power specification

    10Kw

    Specification of DC input

    Nominal voltage specification

    DC48-AC220V

    DC48-AC110V

    Working voltage Range (Normal working  battery voltage)

    40V-64V (DC 48V power supply)

    Low voltage warning

    42.0Vdc ±1.2Vdc (DC 48V power supply)

    Low voltage and outage

    40.0Vdc ±1.2Vdc (DC 48V power supply)

    Low voltage recovery

    48.0Vdc ±0.3Vdc (DC 48V power supply)

    High voltage warning and outage

    64.0Vdc ±1.2Vdc (DC 48V power supply)

    High voltage recovery

    62.0Vdc ±1.2Vdc (DC 48V power supply)

    Contravariant  Rate

    =90%

    DC first mode,

    44Vdc ±1.2Vdc (DC 48V power supply)

    DC first mode, turn to gird supply, battery low voltage recovery

    54.0Vdc ±1.2Vdc (DC 48V power supply)

    Specification of  AC input

    Nominal voltage specification

    220VAC system

    110VAC system

    The voltage wave of input

    Sine wave(grid)

    Sine wave(grid)

    Nominal input voltage

    220Vac/230Vac/240Vac

    110Vac/120Vac/130Vac

    Low voltage off point

    180Vac±4%

    85Vac±4%

    Low voltage recovery

    195Vac±4%

    90Vac±4%

    High voltage off point

    260Vac±4%

    135Vac±4%

    High voltage recovery

    255Vac±4%

    130Vac±4%

    Grid charging rule

    Constant current charging?Constant voltage charging?
         Float charging

     

    Grid supply rate

    =98%

    Transfer time (AC to DC)

    ?4ms

    Transfer time (DC to AC)

    ?8ms

    AC output specification

    Nominal output voltage (V)

    220Vac/230Vac/240Vac

    110Vac/120Vac/130Vac

    Output voltage Range

    ±10% rms

    Nominal output rate (Hz)

    50Hz±0.3Hz/60Hz±0.3Hz

    Power Factor

    1.0

    The wave of output

    Pure sine wave

    THD

    =3% (   loading)

    Over loading protect

    (SMPS load)

    (110%<loading  <125%)±10% :15 minuets later, off the output voltage

     

    (125%<loading  <150%)±10% :1 minuet later, off the output voltage

     

    (loading  >150%)±10% :20 seconds later,  off the output voltage

     

    Other instructions

    Continuous running time

    Could be continuous running

    Normally start expand in vain

    =Nominal power×2.5%

    Saving mode expand in vain

    =6w

    Safety certificate

     CE(EN62040-1)     EMC:EN62040-2 C2,

    Communication port

    RS232/RS485

    Cooling

     With fans

    Noise (dB?1 meter)

    <60dB

    Using  environment  temperature (?)

    -10~+45

    Storage environment  temperature (?)

    -20~+55

    Using environment humidity

    0-95%  humidity

    Using altitude (m)

    =5000

    Display mode

    LED light+ LCD display

    Warning model

    Buzzer sound warning

    Protect  function

    Low voltage protect, High voltage protect, higher temperature protect, short circuit protect, leak electricity protect, Over current protect, over loading protect, low voltage recovery, high voltage recovery, intelligent temperature-control, accident warning;

    Water proof

    IP20/ It is could be customized

    Specs of solar discharging and charging controller

    Specification

    48V100A

    Nominal Power (W)

    5000

    Nominal charging current (A)

    100

    Nominal DC voltage (V)

    48V

    PV Max Voltage (V)

    <100

    PV Max power (W)

    5000

    Over charging  protect voltage of battery (V)

    58.4

    Over charging  recovery voltage of battery (V)

    58.0

    Constant charging voltage of battery (V)

    54.0

    Over discharging  warning voltage of battery (V)

    40

    Protect  function

    Protect opposite charging in the night, Solar connect opposite.

    Control mode

    PWM/MPPT

    Any other instructions

     

    The specs of Charger

    Model

     2~5 KW

    DC voltage

    48V

    Charging current

    30A~100A

    The size of breaker

    20A~120A

    The size of breaker

    130A

    Charging voltage

    According the specs of battery

    Charging short circuit protect

    Breaker protect

    Charging rule

    Constant current charging?Constant voltage charging?Float charging

    Charging period transfer

    ? constant current charging stage: AC current input, the charger will run at the maximum constant current until the constant voltage phase.
    ? Constant voltage charging stage: The charger will maintain a constant voltage mode and then the voltage drops to the float voltage.
    The minimum time is 1 hour and the maximum time is 12 hours.
    Float stage: In the float stage, the voltage will remain at the float voltage.
    ? If you reconnect the AC, the voltage drops below 40Vdc, the charger will restart the above cycle.
    ? If the charger remains floating for 10 days, the charger will start cycling again.

    5. The specs of BMS board

    Item

    Options

    Item

    Options

    BMS working voltage range

    40~58.4V

    BMS working

    <3W

    BMS working temperature

    -20~65?

    BMS working humidity range

    5~90

    Single cell voltage test range

    0~5V

    Voltage test accuracy of one series cell

    ±10mV

    Single cell voltage test rate

    =10mS

    Total voltage test channel

    1

    Total voltage test accuracy

    0.5% FSR

    Total voltage test range

    50~1000V

    Temperature test accuracy

    ±1?

    Temperature test range

    -40~125?

    Insulator detection period

    =10ms

    Current test accuracy

    <±1% FSR

     

     

    SOC estimate accuracy

    5%

     

     

    Balance mode

    passivity

    6. Product picture (It is could be customizable.)

    ??18.png

    7.Home / Industrial Energy Storage System Functional Description    

    7.1 Features

    ? Overload capacity can be as high as rated power (300% for 20 seconds).;

    ? Inverter adopts low static current design, energy saving mode will reduce no-load loss period detection (3 seconds detection period) / 3W (30 seconds detection period), priority mode using maximum battery power, with different protection, battery low voltage cut out points can be set manually.

    ? Inverter adopts 4th-order intelligent charge design with power factor correction function, charging efficiency is higher.

    ? There is a 15-second delay before the AC restore conversion is completed, protecting the load from running stably (when the AC input is a generator).

    ? Mains and battery 10 ms conversion time to ensure the continuity of power; optional mains voltage range (184-253Vac or 154-253Vac) depending on the load type.

    ? The maximum rated charging current up to 90A, 0-100% adjustable.?

    ? Battery / mains priority mode setting switch; status display module, a variety of alarm fault indication, easy operation and maintenance.

    ? Battery overcharge, over discharge, high temperature, low temperature, over-current protection function, automatically shut off the battery pack output when a serious fault.

    ? Batteries single cell balancing function, balanced way for the passive balance, the equilibrium current of about 100mA, battery cells to maintain consistency.

    ? Battery pack insulation testing, storage system battery pack insulation alarm, to prevent leakage caused by a security incident.

    ? Battery thermal management function, the battery temperature is high, start the fan to complete the heat exchange, reducing the battery temperature.

    ? Battery pack power management function, when the battery voltage is lower than 40V, the battery pack is stopped so power supply, into the zero power mode.

    ? Battery pack real-time information data display function, the battery pack SOC, protection status, charge and discharge current, cell voltage, battery temperature and other information can be displayed on the LCD screen for user inquiries.

    7.2External communication and program control

    Energy storage system with external communication and programmable RS485, RS232 communication interface, can be used for energy storage systems and peripherals in real-time communication, data interaction. Communication speed 250Kbps or 500Kbps, communication protocol can be customized according to customer requirements.

Send your message to this supplier
To:  

Nantong Ningyuan Automation Technology Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
You May Like
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :